What are the usage conditions for the fire inspection cabinet?
Release time:
2022-12-12
Author:
Source:
Abstract
As we all know,Fire inspection cabinetis a device for completing low-frequency and low-speed self-operation inspection control of fire pumps and sprinkler pumps. During the use of the equipment, certain conditions must be met before operation to achieve usage standards. To help more users understand, the following are the conditions introduced by the fire inspection cabinet manufacturer.
1. Indoor temperature should be between 5°C and 60°C.
2. Altitude should not exceed 1000 meters.
3. Monthly average relative humidity should not exceed 90%, and daily average should not exceed 95%.
4. Air quality: The surrounding air may be contaminated by dust, smoke, corrosive gases, vapors, or salt mist, and the pollution level must not exceed level two as per the current GB/T5582 standards.
5. Earthquake intensity should be at level 8.
Why use a fire inspection cabinet
The fire inspection cabinet is an inspection method that meets the industry standards of the security department, characterized by high safety, low current, and low power consumption. However, many unclear users do not understand why this device is necessary, so this article provides an introduction.
Significance of the fire inspection cabinet: Fire water supply equipment is a basic component of fixed fire water supply systems. Although this part does not account for a high cost in the overall building fire system (usually less than 1%), countless experiences have proven that the success of initial firefighting mainly depends on the integrity of this equipment. With the rapid development of society, there are more and more public places with high-density populations such as high-rise buildings, hospitals, hotels, and shopping malls, making fire safety tasks even more important.
The fire inspection cabinet consists of two parts: main circuit patrol and non-pressure patrol of fire equipment. It can complete low-speed automatic patrol of the main control circuit and water pumps. When there are no system fire commands and all fire equipment system switches are in automatic mode, the fire pump can automatically check and operate. The automatic detection cycle can range from several hours to hundreds of hours; the cycle clock automatically starts the inspection program and has a manual inspection function. Automatic fire patrol water supply equipment is an important part of the fire system, working in conjunction with fire alarm systems to assess fires until an alarm is issued. Ultimately, conducting patrols on fire water supply equipment is one of the fundamental purposes.
During the inspection process, if a pump malfunctions, it will provide fault alarm information. When overpressure, underpressure, phase loss, output overcurrent, or short circuit occurs, the controller will send alarm information to the fire control center. This result of automatic checks can ensure that fire pumps do not rust or fail. Intelligent devices bring convenience to people's production and life while saving energy for the country and meeting higher demands of modernization.