Conditions for the use of fire inspection cabinets
Release time:
2022-12-20
Author:
Source:
Abstract
As we all know,Fire Inspection Cabinetis a device for completing low-frequency and low-speed self-operation inspection control of fire pumps and sprinkler pumps. During the use of the equipment, certain conditions must be met before operation to achieve usage standards. To help more users understand, the following are the conditions introduced by the fire inspection cabinet manufacturer.
1. Indoor temperature should be between 5°C and 60°C; 2. Altitude should be less than 1000 meters.
3. The average monthly relative humidity should not exceed 90%, and the daily average should not exceed 95%.
4. Air quality: The surrounding air may be contaminated by dust, smoke, corrosive gases, vapors, or salt mist, and the pollution level must not exceed the second level in the current GB/T5582.
5. Earthquake intensity should be at level 8.
The fire inspection cabinet is a method of inspection that complies with industry standards set by the Ministry of Security, featuring high safety, low current, and low power consumption. However, many unclear users do not understand why this device is necessary.
The significance of the fire inspection cabinet: Fire water supply equipment is a fundamental component of fixed fire water supply systems. Although this part does not account for a high cost in the overall building fire system (usually less than 1%), countless experiences have proven that the success of initial firefighting mainly depends on the integrity of this equipment. With rapid social development, there are more public places with high-density populations such as high-rise buildings, hospitals, hotels, and shopping malls, making fire safety tasks even more important.
The fire inspection cabinet consists of two parts: main circuit patrol and pressure-free patrol of fire equipment. It can complete low-speed automatic patrols of the main control circuit and water pumps. When there are no system fire commands and all system switches of fire equipment are in automatic mode, the fire pump can automatically check and operate. The automatic detection cycle can range from several hours to hundreds of hours, with a cycle clock automatically starting the inspection program and having a manual inspection function. Automatic fire patrol water supply equipment is an important part of the fire system, working in conjunction with devices like fire alarm systems to assess fires until an alarm is issued. Ultimately, one of the fundamental purposes is to conduct inspections on fire water supply equipment.
During the inspection process, if a pump malfunctions, it will provide fault alarm information. When overpressure, underpressure, phase loss, output overcurrent, or short circuit occurs, the controller will send an alarm message to the fire control center. This result of automatic checks can ensure that fire pumps do not rust. Intelligent devices bring convenience to people's production and life while saving energy for the country and meeting higher modern requirements.