Home
Product Center
Brand authorization cabinet
Low voltage complete equipment
High voltage complete equipment
Box type substation
Customized sheet metal processing
ABB MDrail-E low-voltage distribution box/cabinet
Schneider BloketSet 5000 Low Voltage Complete Equipment
Siemens Siboard Low Voltage Electrical Cabinet
Chnt Powgrid-s Distribution Cabinet
Low voltage switchgear
Power Distribution Box
Measuring Box
Cable Branch Box
Fire Intelligent Control Equipment
High voltage complete switchgear
Cable branch box
XBJ1 Compact 12kV (10kV) Box type Substation
XBZ1 Intelligent 12kV (10kV) Box type Substation
PMK series console
Control panel
Blog
Company News
Industry News
About Us
Company Overview
Corporate Culture
Development History
Honor
Production Base
Partner
Contact Us
30
2021-08
Inspection of box-type substations before use
After the installation or maintenance of a box-type substation, certain inspections and tests should be conducted before it is put into operation. This includes checking whether the interior of the substation is clean, whether the operating mechanisms are flexible, whether the main electrical appliances are flexible and reliable, whether the auxiliary contacts of the electrical appliances are reliable and accurate, whether the instruments and relays operate accurately, whether the ratio of the modified electric meter to the transformer is correct, whether the wiring polarity is correct, whether all electrical installation nuts are tightened, whether the installation is firm and reliable, whether the bus connections are good, and whether the clamp parts are installed securely. Additionally, it should be verified that the supporting insulators and electrical setting values meet requirements, that the specifications of the fuse cores are correct, and that the contacts of both the main circuit and auxiliary circuit comply with the requirements of the electrical schematic. The internal protection grounding system of the product should be less than 0.01 ohms, and each part should undergo a withstand voltage test according to its corresponding voltage level.
2021-08-30
27
Selection of internal components for box-type substations
Technical key points for component selection in box-type substations: selection of high-voltage side receiving equipment, transformer selection, low-voltage distribution component selection, etc.
2021-08-27
26
What is a combined box-type substation?
The combined box-type substation places the transformer body, high-voltage load switch, fuse, and high and low voltage joints within a common sealed oil tank, with transformer oil serving as the insulating medium between the live components and the ground. This type of distribution equipment has a compact structure, small size, and is economical and practical.
2021-08-26
25
The overvoltage phenomenon in box-type substations.
In a box-type substation, if the voltage of the relay protection calibration instrument exceeds the maximum allowable operating voltage of the transformer during operation, it is referred to as transformer overvoltage.
2021-08-25
24
The main applications of box-type substations.
In the power system, most loads are inductive loads, which can cause a significant amount of reactive power. Simply put, electrical energy is wasted by the inductive loads in our daily lives. An important device in the box-type substation that can solve this problem is the capacitor compensation cabinet.
2021-08-24
23
The application prospects of box-type substations.
Box-type substations are the main direction for current rural power grid renovation and future substation construction, but there are still some shortcomings in certain aspects, specifically: